Continuous Emissions Monitoring Systems
MIR-FTIR CEM SystemPrint Continuous Emissions Monitoring Systems
- Downloads
-
CEMS Brochure CEMS Brochure -
MIR-FTIR Datasheet MIR-FTIR Datasheet
Measurement Technique
Installed across the majority of the UK’s municipal waste incinerators, the MIR-FT Utilises Fourier Transform Infra-Red (FT-IR) to offer multiple gas measurements simultaneously, including NO, NO2, SO2, NH3, HCl and CO.
With the emissions limits tightening and new gases being introduced, this instrument allows future gas upgrades, providing the solution for today and what may happen tomorrow.
Compliance
Designed to operate under legislation such as 2000/76/EC (WID) and 2001/80/EC (LCPD), The MIR-9000 offers maximum availability and complete compliance with QAL 1 of EN14181
Integration
The MIR-FT would be rack mounted in air conditioned enclosures.
Complete systems would normally comprise of:
• Sample extraction and conditioning probe (with integrated temperature, pressure and flow measurement)
• Heated sample lines
• Automatic calibration units
• Instrument Air drying system
• CDAS Data Acquisition Software
Dual Redundancy System - Under WID, the maximum allowable period for any one episode of abatement or equipment failure must not exceed four hours. Additionally, the total allowance period in a year must not exceed sixty hours.
The a1-cbiss duplex philosophy has therefore been specifically developed to assist you in complying with WID/LCPD by reducing downtime, maximising availability and ensuring you achieve a sound return on your investment.
For further information, please contact us on 0151 666 8300 or email sales@a1-cbiss.com
FEATURES
• Designed for measurements in wet and corrosive sample gases
• Future upgrades possible
• Excellent calibration stability
• Automatic spectral interference corrections
• Fast and simultaneous measurements for multiple gases
• Reproducible and accurate
• Windows based PC driven software with on-board data acquisition
• Capable of automatic QAL 3 checks when used in conjuction with IVIS unit
• MCERTS Certified
MCERTS CERTIFICATION RANGES
NO: 0-200mg/m3 - 0-600mg/m3
NO2: 0-200mg/m3
CO: 0-75mg/m3 - 0-300mg/m3
CO2: 0-25%
SO2: 0-75mg/m3 - 0-500mg/m3
N2O: 0-100mg/m3
HCl: 0-15mg/m3 - 0-90mg/m3
NH3: 0-15mg/m3
H2O: 0-30%
O2: 0-25%
COMPLIANCE
Designed to operate under legislation such as 2000/76/EC (WID) and 2001/80/EC (LCPD), The MIR-9000 offers maximum availability and complete compliance with QAL 1 of EN14181
MCERTS DATA ACQUISITION SOFTWARE
Used in conjuction with CBISS Data Acquisition Software (CDAS)
What is CDAS?
CDAS is the market leading MCERTS accredited (parts A, B, C1 & C2) Data Acquisition Software package that retrieves data from CEMS instruments.
The CDAS software meets the stringent demands of WID, LCPD, EN14181, IPPC and customer specific requirements